Writing.

What we have learned fabricating air distribution and filtration, written down for consultants, contractors and the curious.

Fire damper codes in India: where an FD is mandatory.

21 October 20264 min read

Fire damper codes in India: where an FD is mandatory.

The code is not ambiguous about fire dampers: wherever a duct crosses a fire separation, the penetration is protected or the rating is lost. Where they land, and what your inspector will ask for.

Read the piece →
How to size a jet nozzle: throw, height and the farthest seat.

15 October 20265 min read

How to size a jet nozzle: throw, height and the farthest seat.

The nozzle is the terminal of last resort for tall, long spaces, which is exactly why sizing it wrong is so visible. A working method, without the catalogue lore.

G2 to F9: air filter grades explained without the jargon.

8 October 20265 min read

G2 to F9: air filter grades explained without the jargon.

Filter grades are the most quietly expensive decision in an HVAC system. Pick wrong and you either choke the fan or replace media every month. Here is what the grades actually mean.

Grille or diffuser? Choosing the right terminal device.

18 September 20264 min read

Grille or diffuser? Choosing the right terminal device.

They both sit at the end of a duct and both blow air into a room, and yet picking wrong shows up within a week of commissioning. Here is how the choice actually works.

Types of aluminium air grilles, and where each one belongs.

5 September 20265 min read

Types of aluminium air grilles, and where each one belongs.

Linear bar, fixed pattern, double deflection, floor, sill — the same word covers five different products. A field guide to air grilles (yes, people spell it air grill) and the room each one was born for.

What throw distance really means, and how we test it.

2 August 20265 min read

What throw distance really means, and how we test it.

Throw is the most quoted and least understood number in air distribution. A supplier's throw figure and your experience of it can differ by meters, and the reasons are physical.

Weather louvers: choosing blades for a monsoon climate.

12 July 20264 min read

Weather louvers: choosing blades for a monsoon climate.

A louver is the building's nostril, and on the west coast of India it takes a beating for four months a year. Drainable blades, screens and free area, explained for plant rooms and facades.

Dampers explained: VD, FD and MFD in plain language.

21 June 20264 min read

Dampers explained: VD, FD and MFD in plain language.

Three letters separate a balanced system from a fire hazard. Dampers are the least glamorous product we make and the one we are most careful with.

Air Filtration & HVAC Writing: Guides from the Plant | Hayan HVACR