Air glossary.

Thirty terms from filtration, distribution and control, defined in plain language: two sentences each, no catalogue lore. Where a term has a product behind it, the link follows the definition.

AHU (Air Handling Unit)
The plant that conditions a building's air: fan, filter bank, coils and damper sections in one casing. Most of this catalogue lives inside one.
FCU (Fan Coil Unit)
A small fan-and-coil unit serving a single room or zone, common in hotels and apartments. Its washable panel filter is the room-side first line of defence.
Pre-filter
The first, coarse stage of a filter train, catching dust and lint before they reach coils and fine media. Protecting every stage downstream is its whole job. Air Filtration Products →
Fine filter
The second-stage filter, M5 to F9, removing pollen, smoke and bacteria-carrying dust. The stage that decides indoor air quality in a commercial building.
HEPA filter
The absolute stage: H13 and H14 filters removing 99.95 to 99.995 percent of particles at 0.3 micron. Specified for operation theatres, pharma cleanrooms and electronics. HEPA filters →
EPA filter
Efficient Particulate Air filters, H10 to H12: the class between fine filters and HEPA. For cleanrooms that do not need H13, specifying it anyway wastes pressure drop. EPA filters →
Filter grade
The letters that describe what a filter catches: G for coarse, M and F for fine, E and H for EPA and HEPA. Coarse before fine is the rule; each stage exists to protect the next.
Pressure drop (ΔP)
The resistance a filter or terminal adds to the airstream, in pascals. Every extra pascal is fan power, paid for the life of the installation.
Face velocity
Airflow divided by face area, in metres per second. Above design velocity, dust holding falls, pressure drop climbs and noise rises.
Dust-holding capacity
How much dust a filter loads before reaching its final pressure drop. Bag and deep-pleat formats carry more media, hold more dust and run longer between changes.
Arrestance
The share of coarse dust a filter captures by weight, the right measure for pre-filters. Efficiency, its counterpart, measures the finest particles and belongs to fine and absolute stages.
Grille
A frame of blades at the end of a duct, aimed at a room. Its strength is direction: air steered away from desks, beds and doorways. Air Distribution Products →
Diffuser
A terminal that sends air into a spreading, mixing pattern through swirl vanes or radial cones. It pulls room air into the stream and delivers comfort at low velocity.
Linear slot diffuser
A continuous line of slots on one plenum, the architectural standard for modern office ceilings. One-way to four-way patterns from a single linear face. linear slot diffusers →
Swirl diffuser
Fixed radial vanes that spin supply air as it leaves the face. High induction mixes it with room air within a short distance, the choice for high-airflow ceilings. swirl diffusers →
Jet nozzle
A focused, aimable column of air for tall and long spaces, with throws ordinary terminals cannot reach. The terminal for airports, auditoriums and halls. jet nozzles →
Throw distance
How far air travels before its velocity falls to a reference speed, usually half a metre per second. It depends on the airflow you actually run, not the catalogue maximum.
Terminal velocity
The reference speed at the end of the throw, roughly where a seated person stops noticing the air. A lower reference velocity means a longer stated throw for the same terminal.
Induction
Room air pulled into the supply stream by a diffuser's or nozzle's discharge. High induction means rapid mixing and even temperatures close to the terminal.
Disk valve
A disc in a ring or spigot for exhaust and spot supply: closed tight or open to a conical spread. The toilet-extract workhorse. disk valves →
Plenum box
The sheet-metal box behind a diffuser or grille that connects duct to face and evens the airflow. Sized to keep pressure drop and noise low. plenum boxes →
Volume control damper
The tap of the duct system: blades that throttle airflow at branches and terminals. Balancing engineers use them to bring every outlet to design flow. volume control dampers →
Fire damper
A life-safety device that seals a duct where it penetrates a fire-rated wall, slab or shaft. When heat arrives, a fusible link or actuator closes the blades and the duct stops carrying fire. fire dampers →
Non-return damper
Gravity blades that open to airflow and fall shut against reverse flow. For exhaust stacks and plant rooms where wind or standby fans push air the wrong way. non-return dampers →
Pressure relief damper
A weighted or spring-loaded door that opens when duct pressure passes its set point and closes again below it. Keeps rooms and plant within design pressure. pressure relief dampers →
Air balancing
Commissioning the system so every terminal delivers its design airflow, damper by damper. Done once at handover, then again every time the system changes. Air Control Products →
Louver
The building's nostril: blades that admit air while shedding rain, with mesh behind against birds and insects. Drainable blades go further, walking wind-driven water out of the frame. fresh air louvers →
Free area
The open fraction of a louver or grille face that passes air. Every screen and drainable profile costs free area, and free area lost is fan power spent.
Return air
Room air drawn back to the AHU for reconditioning instead of discharge. Return grilles, risers and transfer paths are half of every system. return air risers →
Fresh air
Outdoor air the system introduces for ventilation, taken in through the louver and its screens. How well the building breathes is decided at that opening.